The C.A.P. MLC-16 and MLC-16a represents the latest in LARGE SCALE lighting control. They control up to SIXTEEN 1000-watt HID lights from one time-clock or controller. Run 80 amp power to the MLC-16 or MLC-16a, and all of the outlets are controlled by one 120 volt “trigger cable”. You can plug the “trigger cable” into a standard 24 hour timer or lighting controller.
The MLC-16 features standard 240 volt style (NEMA 6-15) outlets, which your ballasts are plugged into. The MLC-16a uses 120 volt style (NEMA 5-15) outlets which allows for running your ballasts at 240 volts without having to change out your ballast power cords.
Each contains 4 banks of 4 lights. Each bank of 4 lights is protected by a 20 amp circuit breaker.
These light controllers need to be hardwired. We strongly recommend a licensed electrician install this unit.
Specifications: Trigger Voltage: 120 volts Receptacle Type: MLC-16: Nema 6-15 /// MLC-16a: Nema 5-15 Main Power Voltage: 240 volts Maximum Relay Amperage: 80 amps Minimum Feeder Cable Size: 4 AWG ***Please check local codes for sizing requirements. Maximum Wattage: 16,000 watts/1000 watts per receptacle Operating Temperature Range: 32-120° F Operating Humidity Range: 0-99% RH Relay Operations (minimum): 100,000 Electrical
Warranted against defects in workmanship and parts for THREE Years!
More info (PDF format)
C.A.P. MLC-16 lighting controller (240V): |
$558.95 FREE Shipping |
|
C.A.P. MLC-16a lighting controller (120V): |
$558.95 FREE Shipping |
|
|